Hyundai Santa Fe (DM): Cooling Fan. Repair procedures - Cooling System - Engine Mechanical SystemHyundai Santa Fe (DM): Cooling Fan. Repair procedures

Removal and Installation

Cooling Fan Assembly
1.
Disconnect the battery terminals.
2.
Remove the air cleaner assembly.
3.
Remove the under cover.
4.
Remove the front bumper cover.
 
5.
Disconnect the PWM module connector(A).

6.
Remove the air intake shield(A).

7.
Remove the radiator over flow hose (A) and upper bracket (B), air guard(C).

8.
Loosen the cooling fan mounting bolts and then disconnect the cooling fan assembly (A) from radiator.

9.
Install in the reverse order of removal.
PWM Module
1.
Remove the LH wheel guard.
2.
Disconnec the PWM connectors and then remove the PWM module(A).

Tightening torque :
7.8 ~ 11.8 N.m (0.8 ~ 1.2 kgf.m, 5.8 ~ 8.7 lb-ft)

3.
Install in the reverse order of removal.

Disassembly

1.
Remove the cooling fan(A) from cooling assembly.

Tightening torque:
2.7 ~ 3.2 N.m (0.28 ~ 0.33 kgf.m, 2.0 ~ 2.3 lb-ft)

2.
Remove the fan motor(A) from cooling fan shroud.

Tightening torque:
3.9 ~ 5.8 N.m (0.4 ~ 0.6 kgf.m, 2.8 ~ 4.3 lb-ft)

3.
Install in the reverse order of removal.

Cooling Fan. Schematic Diagrams
Circuit Diagram PWM Circuti Diagram ...

Reservoir Tank. Repair procedures
Removal and Installation 1. Remove the over flow hose(A). 2. Remove the reservoir tank(B). Tightening torque: 7.8 ~ 11.7 N.m (0.8 ~ 1.2 kgf.m, 5.7 ~ 8.6 lb-ft) 3. Install in the reverse order of removal. ...

See also:

Immobilizer Indicator Light (With Smart Key)
This indicator light illuminates for up to 30 seconds: • When the vehicle detects the smart key in the vehicle properly while the Engine Start/Stop Button is ACC or ON. - At this time, you can start ...

Hood Latch Release Handle. Components and Components Location
Component Location 1. Hood latch release handle ...

Description and Operation
Description Automatic transaxle system relies on various measurement data to determine the current control status and extrapolate the necessary compensation values. These values are used to control the ...