Hyundai Santa Fe (DM): Fuel Tank Air Filter. Repair procedures - Evaporative Emission Control System - Emission Control SystemHyundai Santa Fe (DM): Fuel Tank Air Filter. Repair procedures

Removal

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Lift the vehicle.
3.
Disconnect the canister close valve connector (A).
4.
Disconnect the ventilation tube quick-connector (B) from the fuel tank air filter and canister close valve.
Корм для стерилизованных котят - купить корм для стерилизованных котят molina.ru.

5.
Disconnect the vapor tube quick-connector (A).
6.
Remove the canister assembly bracket (D) after removing the mounting bolts (B) and nut (C).

7.
Remove the canister braket (B) installation bolt (A).

8.
Remove the fuel tank air filter & canister close valve assembly (A) after rotating it in the direction of the arrow in the figure.

9.
Release the lever (A), and then separate the canister close valve (B) from the fuel tank air filter (C) after rotating it in the direction of the arrow in the figure.


Installation

Install the component with the specified torques.
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
1.
Install in the reverse order of removal.

Fuel Filler Cap. Description and Operation
Description A ratchet tightening device on the threaded fuel filler cap reduces the chances of incorrect installation, which would seal the fuel filler. After the gasket on the fuel filler cap and the ...

See also:

Interior lamp bulb replacement
WARNING Prior to working on the Interior Lamps, ensure that the “OFF” button is depressed to avoid burning your fingers or receiving an electric shock. 1. Using a flat-blade screwdriver, gently pry ...

Seat Heater (Non-Air Ventilation). Repair procedures
Inspection Front Seat 1. Check for continuity and measure the resistance between terminals. No. Description No. Description 1 Heater cushion + 4 Heater back + 2 NTC + 5 - 3 Ground 6 NTC - Standard value ...

Checking the amount of air conditioner refrigerant and compressor lubricant
When the amount of refrigerant is low, the performance of the air conditioning is reduced. Overfilling also has a negative influence on the air conditioning system. Therefore, if abnormal operation is ...