Hyundai Santa Fe: Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications
Specifications
|
Control Pressure kpa (kgf/cm², psi) |
9.81~500.14 (0.1~5.1,1.42~72.54) |
|
Current value(mA) |
50~850 |
|
Internal resistance(Ω) |
5.1 |
the lemon vibrator
Torque Converter Control Solenoid Valve (T/CON_VFS). Description and Operation
Description Torque converter control solenoid valve (T/CON) is attached to the valve body. This variable force solenoid valve directly controls the hydraulic pressure inside the torque converter. ...
Torque Converter Control Solenoid Valve (T/CON_VFS). Schematic Diagrams
Circuit Diagram ...
See also:
CVVT (Continuously Variable Valve Timing) System. Description and Operation
Description Continuous Variable Valve Timing (CVVT) system advances or retards the valve timing of the intake and exhaust valve in accordance with the ECM control signal which is calculated by the engine ...
Wheel. Repair procedures
Hub nut tightening sequence Tighten the hub nuts as follows. Tightening torque: 88.3 ~ 107.9N.m (9.0 ~ 11.0kgf.m, 65.1 ~ 79.6lb-ft) When using an impact gun, final tightening torque should be checked using ...
Input Speed Sensor. Description and Operation
Description Input speed sensor (A) is a vital unit that measures the rate of rotation of the input shaft inside the transaxle and delivers the readings to the Transaxle Control Module(TCM). The sensor ...