Hyundai Santa Fe: Purge Control Solenoid Valve (PCSV). Specifications
Specification
|
Item |
Specification |
|
Coil Resistance (Ω) |
19.0 ~ 22.0 [20°C(68°F)] |
Purge Control Solenoid Valve (PCSV). Description and Operation
Description Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds ...
Purge Control Solenoid Valve (PCSV). Schematic Diagrams
Circuit Diagram ...
See also:
Troubleshooting
Troubleshooting Guide Before Thinking The Product Has Malfunctioned 1. Errors which occur during the operation or installation of the device may be mistaken as a malfunction of the actual device. 2. If ...
Rear Console Cover. Repair procedures
Replacement • Put on gloves to protect your hands. • When prying with a flat-tip screwdriver, wrap it with protective tape, and apply protective tape around the related parts, to prevent damage. • ...