Hyundai Santa Fe: Cooling Fan. Description and Operation
Description
Control the cooling motor voltage in according to the duty(300Hz)
of ECM.
[ECU → PWM Input Signal(SI : 300Hz)]

|
SI Duty |
Motor Voltage (V) |
|
|
10% |
0 |
─ |
|
30% |
4.1 |
± 0.65 |
|
60% |
8.2 |
± 0.66 |
|
70% |
9.57 |
± 0.67 |
|
90% |
12.5 |
─ |
[Cooling Fan Operation Condition]
|
A/C Switch |
A/C Pressure (Kgf/cm² G) |
Vehicle Speed (Km/h) |
Coolant Temp (°C) |
Duty (%) |
|
OFF |
─ |
V < 45 |
98 above |
35 |
|
45 ≤ V < 80 |
101 above |
40 |
||
|
80 ≤ V |
105 above |
80 |
||
|
ON |
A/C Pressure < 6 |
ALL |
105 above |
90 |
|
6 ≤ A/C Pressure < 12 |
V < 45 |
82 above |
30 |
|
|
45 ≤ V < 80 |
96 above |
40 |
||
|
80 ≤ V |
96 above |
60 |
||
|
12 ≤ A/C Pressure < 15.5 |
V < 45 |
101 above |
70 |
|
|
45 ≤ V < 80 |
-30 above |
40 |
||
|
80 ≤ V |
82 above |
60 |
||
|
15.5 ≤ A/C Pressure |
V = 0 |
-30 above |
60 |
|
|
0 < V |
-30 above |
90 |
Cooling Fan. Components and Components Location
Components 1. Upper air guard 2. PWM module 3. Cooling fan shroud 4. Fan motor 5. Cooling fan ...
Cooling Fan. Specifications
Specification Fuction Specification Maximum Drive Capability 250 W 21.0 + 10% A Input Signal Frequency 300 ± 5% Duty 10, 30 ~ 90 % Voltage level HI 0.7 V above LOW 0 ~ 1.9 V ...
See also:
SS-A Solenoid Valve(ON/OFF). Description and Operation
Description SS-A solenoid valve is attached to the valve body and is an on/off solenoid valve that is used to change gears. SS-A Solenoid valve(ON/OFF) is installed at valve body. ...
Oil Pan. Repair procedures
Removal 1. Remove the drive belt. 2. Remove the A/C compressor. 3. Remove the A/C compressor bracket (A). 4. Drain the engine oil. 5. Remove the oil pan (A). Insert the blade of SST (09215-3C000) ...
Specifications
Specifications Smart Key Unit Items Specification Rated voltage DC 12V Operating voltage DC 9 ~ 16V Operating temperature -22°F ~ 167°F (-30°C ~ 75°C) Load Max. 2.9mA (When welcome light function off) ...