Hyundai Santa Fe: Cooling Fan. Description and Operation
Description
Control the cooling motor voltage in according to the duty(300Hz)
of ECM.
[ECU → PWM Input Signal(SI : 300Hz)]

|
SI Duty |
Motor Voltage (V) |
|
|
10% |
0 |
─ |
|
30% |
4.1 |
± 0.65 |
|
60% |
8.2 |
± 0.66 |
|
70% |
9.57 |
± 0.67 |
|
90% |
12.5 |
─ |
[Cooling Fan Operation Condition]
|
A/C Switch |
A/C Pressure (Kgf/cm² G) |
Vehicle Speed (Km/h) |
Coolant Temp (°C) |
Duty (%) |
|
OFF |
─ |
V < 45 |
98 above |
35 |
|
45 ≤ V < 80 |
101 above |
40 |
||
|
80 ≤ V |
105 above |
80 |
||
|
ON |
A/C Pressure < 6 |
ALL |
105 above |
90 |
|
6 ≤ A/C Pressure < 12 |
V < 45 |
82 above |
30 |
|
|
45 ≤ V < 80 |
96 above |
40 |
||
|
80 ≤ V |
96 above |
60 |
||
|
12 ≤ A/C Pressure < 15.5 |
V < 45 |
101 above |
70 |
|
|
45 ≤ V < 80 |
-30 above |
40 |
||
|
80 ≤ V |
82 above |
60 |
||
|
15.5 ≤ A/C Pressure |
V = 0 |
-30 above |
60 |
|
|
0 < V |
-30 above |
90 |
Cooling Fan. Components and Components Location
Components 1. Upper air guard 2. PWM module 3. Cooling fan shroud 4. Fan motor 5. Cooling fan ...
Cooling Fan. Specifications
Specification Fuction Specification Maximum Drive Capability 250 W 21.0 + 10% A Input Signal Frequency 300 ± 5% Duty 10, 30 ~ 90 % Voltage level HI 0.7 V above LOW 0 ~ 1.9 V ...
See also:
Curtain air bag
❈ The actual air bags in the vehicle may differ from the illustration. Curtain air bags are located along both sides of the roof rails above the front and rear doors. They are designed to help ...
If the engine stalls at a crossroad or crossing
If the engine stalls at a crossroad or crossing, set the shift lever in the N (Neutral) position and then push the vehicle to a safe place. ...
Spark Plug. Description and Operation
Description A spark plug is a device for delivering electric current from an ignition system to the combustion chamber of a spark-ignition engine to ignite the compressed fuel/air mixture therein by means ...