Hyundai Santa Fe: Cooling Fan. Description and Operation
Description
Control the cooling motor voltage in according to the duty(300Hz)
of ECM.
[ECU → PWM Input Signal(SI : 300Hz)]

|
SI Duty |
Motor Voltage (V) |
|
|
10% |
0 |
─ |
|
30% |
4.1 |
± 0.65 |
|
60% |
8.2 |
± 0.66 |
|
70% |
9.57 |
± 0.67 |
|
90% |
12.5 |
─ |
[Cooling Fan Operation Condition]
|
A/C Switch |
A/C Pressure (Kgf/cm² G) |
Vehicle Speed (Km/h) |
Coolant Temp (°C) |
Duty (%) |
|
OFF |
─ |
V < 45 |
98 above |
35 |
|
45 ≤ V < 80 |
101 above |
40 |
||
|
80 ≤ V |
105 above |
80 |
||
|
ON |
A/C Pressure < 6 |
ALL |
105 above |
90 |
|
6 ≤ A/C Pressure < 12 |
V < 45 |
82 above |
30 |
|
|
45 ≤ V < 80 |
96 above |
40 |
||
|
80 ≤ V |
96 above |
60 |
||
|
12 ≤ A/C Pressure < 15.5 |
V < 45 |
101 above |
70 |
|
|
45 ≤ V < 80 |
-30 above |
40 |
||
|
80 ≤ V |
82 above |
60 |
||
|
15.5 ≤ A/C Pressure |
V = 0 |
-30 above |
60 |
|
|
0 < V |
-30 above |
90 |
Cooling Fan. Components and Components Location
Components 1. Upper air guard 2. PWM module 3. Cooling fan shroud 4. Fan motor 5. Cooling fan ...
Cooling Fan. Specifications
Specification Fuction Specification Maximum Drive Capability 250 W 21.0 + 10% A Input Signal Frequency 300 ± 5% Duty 10, 30 ~ 90 % Voltage level HI 0.7 V above LOW 0 ~ 1.9 V ...
See also:
Rear Door Window Glass. Components and Components Location
Component Location 1. Rear door window glass ...
TPMS Sensor. Description and Operation
Description 1. Function A. By detecting the pressure, temperature, acceleration, and battery condition, transmit information to ECU by a wireless RF. B. Wheel location is recognized by comparing with Wheel ...
Components and Components Location
Component Location 1. Fender assembly ...