Hyundai Santa Fe (DM): Power Window Motor. Repair procedures - Power Windows - Body Electrical SystemHyundai Santa Fe (DM): Power Window Motor. Repair procedures

Inspection

Front Power Window Motor
1.
Disconnect the negative (-) battery terminal.
2.
Remove the front door trim.
3.
Disconnect the connector (A) from the motor.
(A : Safety, B : Standard)

4.
Connect the motor terminals directly to battery voltage (12V) and check that the motor operates smoothly. Next, reverse the polarity and check that the motor operates smoothly in the reverse direction. If the operation is abnormal, replace the motor.

5.
Connect the terminal No. 2 and No. 3 to battery voltage (12V) and check that the motor operates smoothly when connecting the terminals below.

Rear Power Window Motor
1.
Disconnect the negative (-) battery terminal.
2.
Remove the rear door trim.
3.
Disconnect the connector (A) from the motor.

4.
Connect the motor terminals directly to battery voltage (12V) and check that the motor operates smoothly. Next, reverse the polarity and check that the motor operates smoothly in the reverse direction. If the operation is abnormal, replace the motor.


Power Window Switch. Components and Components Location
Components Driver Power Window Switch Assist Power Window Switch Rear Power Window Switch ...

See also:

To defrost outside windshield
1. Set the temperature to the extreme hot (HI) position. 2. Set the fan speed to the highest (extreme right) position. 3. Press the defrost button (). 4. The outside (fresh) air position will be selected ...

Canister Close Valve (CCV). Description and Operation
Description Canister Close Valve (CCV) is installed on the canister ventilation line. It seals evaporative emission control system by shutting the canister from the atmosphere when leakage detecting system ...

Components and Components Location
Component Location 1. Automatic transaxle 2. Inhibitor switch 3. Transaxle Control Module (TCM) 4. Valve body cover 5. Solenoid valve connect 6. Oil temperature sensor 7. Valve body assembly 8. Line Pressure ...